Valcom VIP-801 Networked Page Zone Extender
Valcom VIP-801 Networked Page Zone Extender Summary
Valcom VIP-801
The VIP-801 Networked Page Zone Extender enables voice access to a single zone of one-way paging over an IP-based LAN/WAN. This allows page zone extension anywhere on the network.
Mounting
The VIP-801 is designed for wall or table mounting.
Table: Provided with the VIP-801 are four rubber stick on feet. Peel these feet off their carrier backing and place at the four corners of the bottom of the unit.
Wall: Using the template and instructions provided, secure the VIP-801 to the wall.
Power Connections
The preferred method of powering a VIP-801 is via a power over Ethernet switch meeting the 802.3af specification. If the rear panel barrel connector is used for power, the preferred power supply is a Valcom VIP-324. Make all required signal connections before applying power to the unit. If powering via 802.3af, make sure all signal connections via the back panel are made then connect the VIP-801 to the Ethernet switch.
If power is supplied via the barrel connector, make sure all signal connections are secure. Attach the unit to the network via the front panel RJ-45 Ethernet connector. Apply power by plugging the power supply into the VIP-801 via the barrel connector on the rear of the VIP-801.
Network Connection
The VIP-801 has one CAT-5 RJ-45 network connector on the front panel. Use one of the supplied CAT-5 patch cables to connect the VIP-801 to an Ethernet switch. If the Ethernet switch is 802.3af compliant the VIP-801 will draw power from it.
Signal Connections
The VIP-801 has 4 I/O connectors on the rear panel:
RCA jack for AUX audio input
- 2 Pin screw terminal for audio output
- 6 Pin screw terminal for relay connections
- 4 Pin screw terminal for audio input and contact closure input
AUX Input:
Local audio input is via the rear panel RCA jack. Nominal input impedance is 600 Ohms. Connect any compatible audio source using an RCA patch cable.
Audio Channels:
Access to the networked audio is via screw terminals on the rear panel. The audio input and contact closure input share a four pin screw terminal connection. Neither input is polarity sensitive. The contact closure is on the right two terminals and is labeled “CC”.
Relay Channels: Access the two form C relays is provided via a six pin screw terminal block. The relays are labeled K1 and K2. Each relay is brought out on three terminals. The common contact is the middle terminal with the normally closed contact on the left and the normally open contact on the right. Relay contacts are rated for 1A @ 24VDC.
Status Indicator Lights:
The VIP-801 has 3 status indication lights on the front panel:
STATUS: Flashes to indicate power.
LINK: Indicates 100 Mbit Ethernet connection when illuminates. No activity indicates 10 Mbit connection.
ACT: Indicator flashes to indicate network activity.
Valcom VIP-801 Features
- 1 Audio Output & Input
- 1 Contact Closure Input
- 2 Programmable Form C Relay Contacts
| Valcom VIP-801 Core Features |
- Peer-Peer, No Server Required
- Auto Destination Programmable
- DTMF Dial Select - 1024 Zones
- 1 to 11 Digit Dial Plans
- Two Way – Transmit / Receive
- POE 802.3af, Class 3, or Local Power 24 VDC
- Can Use DHCP Servers to Acquire IP Addresses
- Easy Windows® Based Setup
- Contact Closure for AUX Audio Input, Audio Indication, Door Unlocking
- 1 RJ45 Ethernet Connection
- Front Panel Activity LED
- Network Activity LEDs
- Radio Link w/Mic Closure/VOX
- Point to Point, Zones, Groups, All Call
- SIP, UDP, Multicast
- Local Aux Analog Input (RCA Jack) Mutes Aux During Page
- Programmable Contact Closure Activation or VOX Activation
- Audio & Contact Closure Per Port
- Applications
- Paging Analog or IP Loudspeakers
- Wide Area Voice Notification System
- Radio Link Remote Audio Monitoring
|
| Valcom VIP-801 Specifications |
- Protocols
- DHCP, IGMP v3, UDP, TCP, HTTP, Telnet, FTP
- Voice Algorithm
- G.711 (64kbits/s)(ulaw)
- Echo Suppression
- Electrical Properties
- Voltage: 24 Vdc @ 250 mA
- IEEE 802.3af compatible, class 3 device
- Regulatory: FCC Part 15 Class A
- Input
- Analog Device Interface
- 600 Ohm Input Impedance
- VOX and Contact Closure Input
- Output
- Analog Output Interface
- Less Than 50 Ohms output impedance
- Frequency Response: 200 Hz – 3400 Hz
- Relay closure available
|